Regeneration after silica gel absorbing water vapor

Click: Time:2010-12-07 14:40:14

     After silica gel absorbing moisture, the moisture can be removed through thermal desorption . The heating methods are various, such as electrothermal furnace , flue waste heat heating and hot air drying, etc.

    The temperature of desorption heating is controlled between 120 ℃ and 180 ℃ . For blue gel indicator, allochroic silica gel and DL type blue silica gel, the temperature should be controlled between 100 ℃ and 120 ℃. During the regeneration of industrial silica gel of various kinds, the maximum temperature should not be higher than below limit: 

      For coarse-pored silica gel, it should not be higher than 600 ℃; 

    For fined-pored silica gel, it should not be higher than 200 ℃ ;  

      For blue gel indicator (or allochroic silica gel), it should not be higher than 120 ℃ ;  

      For alumino silica gel, it should not be higher than 350 ℃ .

      For silica gel after being regenerated, its moisture should be controlled below 2% for repeated operation.